Verdé Environmental Group

Construction dewatering in Ireland: dry digs, licensed discharge

Design, pumps, settlement and treatment, telemetry and the discharge licence from one Verdé team, on six Dublin and Kildare projects since 2024.

Last updated

Pumping draws the water table down below the digExcavation with a deep well each side: pumping draws the water table into a cone below the dig floor, so the dig stays dry.Settlement tankWater tablebeforeDry excavationWater tablewhile pumpingDeep wellDeep well

Which projects has Verdé kept dry?

Six projects across Dublin and Kildare since 2024. Verdé has dewatered for John Sisk & Son at Vantage Data Centers' DUB1 campus in Profile Park, for JJ Rhatigan at Trinity College's E3 Learning Foundry, for John Paul Construction at the Garda operations centre, and at Meta's Fibonacci Square campus.

  • Profile Park, Dublin

    2025For John Sisk & Son
    • The first two phases of Vantage Data Centers' DUB1 campus.
    • A 22-acre development delivering 52 MW of IT capacity.
  • 137–140 Abbey Street Upper

    2025For Gilbert-Ash Ireland

    Dublin 1

    • Dewatering management, regulatory compliance and environmental monitoring.
    • Specialist environmental services through the construction works.
  • Tipper West, Naas

    2025For Ballymore Craddockstown Developments Limited

    Naas, Co. Kildare

    • Continuing support through the ongoing works at Tipper West.
  • Garda Ops Centre

    2024For John Paul Construction

    Dublin 8

    • Dewatering design, installation and management.
    • At the Garda Security Crime Operations Centre.
  • Trinity College, Dublin

    2024For JJ Rhatigan Building Contractors
    • The E3 Learning Foundry development.
    • A 2,200 m² site with an 8 metre dig and secant wall construction.
  • Meta HQ, Dublin

    2024

    Ballsbridge, Dublin 4

    • Fibonacci Square, the former AIB Bank centre.
    • Redeveloped as a Meta campus.

Verdé keeps excavations dry so building can continue, then makes sure the pumped water leaves site legally. One team designs the dewatering system, installs and runs the pumps, settlement tanks, dosing and telemetry, applies for the discharge licence and carries out the sampling and reporting the licence asks for.

Key takeaways

  • Verdé designs, installs and runs dewatering systems with its own crews and equipment.
  • Water to a public sewer needs a Uisce Éireann trade effluent licence; the application fee is €380.
  • Water to a river, stream or groundwater needs a Section 4 licence from the local authority.
  • Pumping to let works go ahead is exempt from EPA registration within Regulation 17's conditions, including an 8-week limit.
  • Recent jobs include Meta's Dublin campus, Trinity College and the Garda operations centre.

Construction dewatering here means controlling groundwater and surface water in excavations so building can continue, then discharging that water legally. The groundwater models behind a dewatering design sit with hydrogeology, the wells themselves are drilled by Verdé's drilling crews, and the work sits inside our wider environmental consultancy offer.

Is this right for you?

This is a fit if

  • Your excavation goes below the water table: a basement, foundations, a pipeline trench or a cofferdam.
  • You need a dewatering design and the discharge licence to go with it.
  • You need pumps, settlement tanks, dosing or telemetry supplied and managed on site.
  • You need discharge sampling and reports to meet licence conditions.

This is not a fit if

  • You need a long-term water supply from a borehole: go to hydrogeology.
  • You only need the groundwater model, with no pumping on site: start with hydrogeology.
  • Oil or fuel is showing in the pumped water: ring the 24/7 line on 0818 714 002.

If it is not a fit, the links above are the right teams.

Where will the water go?

Decide the outfall first, because it decides the licence. Water to a public sewer needs a Uisce Éireann trade effluent licence, water to a river, stream or groundwater needs a Section 4 licence from the local authority, and water taken away by tanker goes to an authorised facility. Discharging without a licence is an offence.

Discharge Route Checker

Four questions. Nothing is stored or sent.

1. Where will the water go?
2. Is the water silty or cloudy?
3. Could it be contaminated: fuel, cement wash or old industrial ground?
4. Is the discharge point near a river, stream or estuary?

Choose where the water will go to see the licence that applies.

How the route checker decides
Discharge routes, licences and add-ons in the route checker
IfThenSource
Water goes to a foul or combined sewerTrade effluent licence from Uisce Éireann (Section 16); €380 application fee, then trade effluent charges; a temporary discharge option on the formUisce Éireann, application form, charges
Water goes to a surface water drain, river or streamSection 4 licence from the local authority; unlicensed discharge is an offenceSouth Dublin County Council
Water goes into the groundSection 4 licence from the local authority, which covers discharges to groundwaterSouth Dublin County Council
Water is taken away by tankerHandled as waste: an authorised collector and facilityWaste management
The water is silty, or not sureAdd settlement tanks and flocculant dosingTreatment train, below
It could be contaminated, or not sureSample and analyse before any discharge; treatment or tankering may followContaminated land
The outfall is near a river, stream or estuaryInland Fisheries Ireland guidelines applyIFI, 2016

How this works: consents under the Local Government (Water Pollution) Act 1977, as amended, as set out by Uisce Éireann and South Dublin County Council. The licensing authority sets the actual conditions.

What changes the set-up

  • If water goes to a public sewer

    then a trade effluent licence from Uisce Éireann is needed, with a €380 application fee; trade effluent charges then apply.

  • If water goes to a river, stream, lake or groundwater

    then a Section 4 licence from the local authority is needed.

  • If the discharge point is near a river or stream

    then Inland Fisheries Ireland's 2016 construction guidelines apply.

  • If the water is silty

    then settlement tanks and flocculant dosing go in before the outfall.

  • If the ground or water may be contaminated

    then the water is sampled and analysed before any discharge, and may need treatment or tankering.

  • If the dewatering is a temporary abstraction to facilitate works

    then it is a listed exemption from EPA registration (EPA), under conditions in Regulation 17 that include an 8-week limit (S.I. 419 of 2024).

  • If pumping will run outside the 8-week temporary limit

    then the abstraction must comply with the 2024 Regulations, so check whether it needs registering.

  • If water is tankered off site

    then it is handled as waste and goes to an authorised facility.

What does the treatment train do?

It turns silty site water into licensed discharge. Water collects in sumps or wells, pumps move it to settlement tanks, pH and flocculant dosing drop out the fines, telemetry tracks quality, and only then does it reach the outfall. Tanks are desludged as solids build up.

How dewatering water is treated before dischargeDewatering treatment train: wells, pumps, settlement tank, pH and flocculant dosing, telemetry, then a licensed outfall.CollectionSumps, wellpointsor deep wellsPumpingLocalised ornetwork pumpsSettlementSettlementtanksDosingpH andflocculantMonitoringIOT telemetry,water qualityOutfallLicensedconnectionDesludgingWaste routeSewerUisce ÉireannSurface waterLocal authorityGroundLocal authority
The outfall's licence sets what may leave site, so the treatment train is sized backwards from those conditions. Sources: Uisce Éireann and South Dublin County Council.
Data behind this graphic
StageEquipmentWhat it controls
CollectionSumps, wellpoints or deep wellsHow far groundwater is drawn down
PumpingLocalised or network pumping systemsFlow out of the excavation
SettlementSettlement tanksCoarse silt
DosingpH and flocculant dosing systemsFine particles and pH
MonitoringIOT telemetry and water quality monitoringWhat is leaving site, live
OutfallLicensed connection to sewer, surface water or groundThe licence conditions
DesludgingTank desludgingSolids removed and sent to a waste route

Sumps, wellpoints or deep wells?

Depth and ground decide it. Sump pumping collects water inside the excavation, wellpoints draw groundwater down around a shallow dig through a ring of small wells, and deep wells with submersible pumps lower it further for deep basements. Verdé installs wellpoints, deep wells and localised or network pumping systems.

Sump pumpingWater seeps into a shallow dig, runs to a sump at its lowest point and is pumped out.Sump pumpingSump
WellpointsA row of closely spaced wellpoints on a header pipe draws the water table just below a shallow dig.WellpointsHeader pipe
Deep wellsDeep wells with submersible pumps draw the water table far below the floor of a deep basement.Deep wellsSubmersible pump
Three ways to keep a dig dry, not to scale. The dashed line is the natural water table; the solid line is the water table while pumping.
Dewatering methods and where each suits
MethodHow it worksSuits
Sump pumpingWater drains to a low point in the dig and is pumped outShallow digs, stable ground, modest inflow
WellpointsA ring of small wells on a header pipe draws water down around the digShallow excavations in sands and gravels
Deep wellsLarger wells with submersible pumps lower groundwater furtherDeep basements and high inflows

The final method comes from the dewatering design, built on baseline laboratory groundwater sampling and a site water balance report.

Does dewatering count as a water abstraction?

Not for registration, if it stays within the exemption. A temporary abstraction to facilitate works is a listed exemption from EPA registration, under conditions in Regulation 17 of the 2024 Regulations that include an 8-week limit. The discharge is a separate matter: the water you pump out still needs a licensed route to sewer, surface water or ground.

Long-term abstractions are different: they follow the 25 and 2,000 m³ a day thresholds for registration and licensing (EPA), and our hydrogeology team prepares those dossiers.

Exempt

Pumping the water out

Taking groundwater out to let the works go ahead is a temporary abstraction, a listed exemption from registration (EPA), within the conditions of Regulation 17, which include an 8-week limit.

Licence needed

Letting the water go

Where the water goes is licensed: by Uisce Éireann for a sewer, by the local authority for surface water and ground. Check your discharge route.

Can you hire the kit without a full system?

Yes. Verdé rents dewatering pumps and hires pH and flocculant dosing systems, and can add settlement tanks, IOT telemetry and water quality monitoring, hose and cable layout and desludging as the job needs them. The same crews install and manage the kit, so hire can grow into a managed system mid-job.

Design and consents

  • Dewatering design
  • Baseline laboratory groundwater sampling and site water balance reports
  • Discharge licence applications to combined sewer, ground or surface water drainage
  • Discharge licence sampling and reporting

Install and run

  • System installation and management
  • Borehole and well installations
  • Localised and network pumping systems
  • Hose and cable layout
  • Settlement tank and water treatment set-up
  • IOT telemetry and water quality monitoring
  • System desludging

Hire

  • Dewatering pump rental
  • pH and flocculant dosing system hire
Ask about pump and dosing hire
What to compare when choosing a dewatering contractor
CriterionVerdéWhat it means for you
ScopeDesign, installation, management, discharge licensing and samplingOne team from the first pump to the final sample.
Crews and kitOwn crews; pumps, tanks, dosing and telemetryEquipment and labour from one supplier.
Track recordSix Dublin and Kildare projects since 2024City-centre basements and large campuses.
MonitoringIOT telemetry and water quality monitoringLive discharge data for licence reporting.
ResponseReply within one working dayYour dewatering brief is answered inside a working day.

Questions about construction dewatering

Still have a question? Call 01 201 1260 or email info@verde.ie.

Who provides construction dewatering in Ireland?

Verdé does, as consultant and contractor in one: dewatering design, installation and management, discharge licensing and sampling, with its own crews and equipment. Its six recent dewatering projects in Dublin and Kildare include Vantage Data Centers' DUB1 campus for John Sisk & Son, Trinity College's E3 Learning Foundry and Meta's campus at Fibonacci Square.

Do I need a Uisce Éireann licence to pump groundwater into the sewer?

Yes. Discharging trade effluent to a public sewer needs a licence from Uisce Éireann under Section 16 of the Local Government (Water Pollution) Acts 1977 and 1990 (Uisce Éireann). The application fee is €380, and the form includes a temporary discharge option (application form). Licensed discharges then pay trade effluent charges, under tariffs approved by the Commission for Regulation of Utilities (Uisce Éireann). Verdé prepares the application and runs the sampling and reporting the licence requires.

Can dewatering water go into a stream?

Only with a Section 4 licence from the local authority, and only once the water meets that licence's conditions. Discharging trade effluent to waters without a licence is an offence (South Dublin County Council). Near rivers and streams, Inland Fisheries Ireland's 2016 construction guidelines also apply. Verdé designs the treatment and prepares the licence application.

How do you stop silt reaching the drain?

With a treatment train between the pumps and the outfall. Water settles in tanks, pH and flocculant dosing drop out the fine particles, telemetry tracks water quality, and tanks are desludged as solids build up. The set-up is sized to the conditions at the outfall, so the water that leaves site meets them.

Can you monitor the discharge remotely?

Yes. Verdé installs IOT telemetry and water quality monitoring on dewatering systems, so readings arrive as live data between site visits. The same records support the discharge licence sampling and reporting Verdé prepares, so the evidence and the report come from one source.

What is a site water balance report?

A site water balance report accounts for the water entering and leaving a site, from groundwater inflow and rain to what is pumped and discharged. Together with baseline laboratory groundwater sampling, it sizes the pumps and tanks and supports the discharge licence application. Verdé prepares both before the system is designed.

Can I hire dewatering pumps and settlement tanks for a Dublin site?

Yes. Verdé rents dewatering pumps and hires pH and flocculant dosing systems on their own, and can add settlement tanks, telemetry, hose and cable layout and desludging if the job grows. Its recent dewatering jobs are on Dublin and Kildare sites. Tell us the expected inflow and the size of the dig, and the right kit follows.

How soon can a dewatering crew mobilise?

Verdé replies to new dewatering enquiries within one working day, with crews based in Kilcoole, Castlebar and Cork. Send the excavation depth and footprint, the ground information, any known groundwater level and your programme dates, so the crew arrives with the right pumps, tanks and hoses on the first visit.

Sources and further reading

  1. About trade effluentUisce Éireann, checked 19 October 2026. Who needs a sewer discharge licence, and its conditions.
  2. Trade effluent licences and application formsUisce Éireann, Current. The €380 application fee, the temporary discharge option and the volume questions.
  3. Trade effluent discharge licencesSouth Dublin County Council, checked 19 October 2026. Section 4 and Section 16 licences.
  4. Guidelines on protection of fisheries during construction works in and adjacent to watersInland Fisheries Ireland, 2016. Working near rivers and streams.
  5. Do I need to register or apply for a licence?Environmental Protection Agency, checked 3 November 2026. The temporary works exemption.
  6. FAQs on water abstraction and associated impoundment regulationEnvironmental Protection Agency, checked 3 November 2026. Thresholds for long-term abstractions.
  7. Trade effluent licensing and chargesUisce Éireann, checked 3 November 2026. The charges a licensed discharge pays.
  8. S.I. No. 419 of 2024, Water Environment (Abstractions and Associated Impoundments) Regulations 2024Irish Statute Book, 2024. Regulation 17: the conditions of the temporary works exemption.

Read this page in Markdown

What happens when you send a dewatering brief

What we ask for

  • Excavation depth and footprint
  • Site investigation reports or ground information
  • Groundwater level, if known
  • Programme dates
  • The proposed discharge point
  • Existing permissions
  • Space and power available for tanks and pumps

Reply

Within one working day.

Phone 01 201 1260 or email info@verde.ie